MPO ADAPTER EMI SHIELDED
Updated: 3 days ago

ADR offers 3 options of MPO adapter:
· Flanged (plastic) type
· Quick connect (plastic) type
· Metal die-cast housing—EMI shielded.
Plastic type is UL rated, withstand temperature of –40/+85 deg. Celsius.
Durability < 30db.
Internal shutter available for dust protection and eye safety
IEC-61754-7 and TIA/EIA 604-5 Compliant for MPO / MTP interfaces. Telcordia GR-1435-Core Compliant.
SPECIFICATIONS
MECHANICAL SPECIFICATIONS: |
Life cycle: <0.3db change, 50 matings Min. |
IEC 61754-7 and TIA/EIA 604-5 Compliant. |
ENVIRONMENTAL SPECIFICATIONS: |
Operating temperature range: -40/+70 ℃ |
MATERIALS: |
Plastic parts: Thermoplastic UL-94-V0 |
Clip & shutter: stainless steel. |
GET YOUR QUOTE
ASK FOR MORE INFO